1. Disconnect the battery from weight. |
Bosch firm generator
|
|
2. Remove a regulator and check length of brushes which should be not less than 6 mm. |
3. If necessary replace brushes which fasten the screw or the soldering (to solder no more than 5 seconds). |
Motorola firm generator |
4. Remove the generator. |
5. Unscrew screws and remove a regulator and a shchetkoderzhatel. |
6. Check length of brushes which should be not less than 6 mm. Brushes change in a set. |